1.
Orthopadie (Heidelb) ; 53(1): 47-55, 2024 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-38095661

RESUMEN

INTRODUCTION: In revision surgery, modular implant components allow the surgeon to tailor the characteristics of the implant to the bone situation. Relative motion can occur at the tapered modular connection, leading to fretting corrosion and subsequent biological reactions, particularly due to poor assembly and contamination of the tapered connection. The aim of this study was to demonstrate whether incomplete assembly and inadvertent contamination of the modular taper causes a change in junction strength. MATERIAL AND METHODS: Modular taper junctions between the neck and the stem (n = 48) were divided into seven groups that differed with respect to contamination (native, contaminated, cleaned) and assembly conditions (secured, pre-tensioned and secured). Contamination was achieved by a combination of porcine bone particles and bovine blood. For each group, the number of rotations of the torque limiter while securing the conical connection was recorded. The implants were subjected to cyclic loading. DIC was used to determine neck rotation, micromotion and axial subsidence. Loosening torque of the locking screw and pull-off forces were measured as an equivalent of residual taper junction strength. RESULTS: Contamination of the taper junction, especially in combination with improper assembly of the components, significantly increased the rotation (35.3 ± 13.7° vs. 2.4 ± 4.4°; p <0.001), micromotion (67.8 ± 16.9 µm vs. 5.1 ± 12.1 µm, p <0.001) and axial subsidence (­34.1 ± 16.9 µm vs. 4.3 ± 10.9 µm; p <0.001) of the neck relative to the stem. CONCLUSION: Intra-operatively, contamination of the taper surface can be identified by the need for multiple turns when tightening the locking screw. Correct cleaning with the new taper cleaning instrument and complete assembly with pre-tensioning may reduce the risk of early failure and fatigue fracture of the modular taper connection.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Animales , Bovinos , Diseño de Prótesis , Falla de Prótesis , Fenómenos Mecánicos
2.
PLoS One ; 18(9): e0291599, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37708193

RESUMEN

BACKGROUND: Despite the success of primary total hip arthroplasty, the number of revisions remains high. Infection, aseptic loosening, periprosthetic fractures and dislocations are the leading causes of hip revision. Current revision stem designs feature a tapered body with circumferential placed longitudinal thin metal splines that cut into the femoral cortex of the diaphysis to provide axial and rotational stability. Modifications to the spline design may help improve primary stability in various bone qualities. The purpose of this study was to evaluate whether the rotational stability of a revision hip stem can be improved by an additional set of less prominent, wider splines in addition to the existing set of splines. It is hypothesized that the additional splines will result in greater cortical contact, thereby improving torsional strength. METHODS AND FINDINGS: The ultimate torsional strength of an established modular revision stem (Reclaim®, DePuy Synthes) was compared to a Prototype stem design with two sets of splines, differing in prominence by 0.25 mm. Five pairs of fresh-frozen human femurs (n = 10) were harvested and an extended trochanteric osteotomy was performed to obtain common bone defects in revision. Stems were implanted using successive droptower impacts to omit variability caused by mallet blows. The applied energy was increased from 2 J in 1 J increments until the planned implantation depth was reached or seating was less than 0.5 mm at 5 J impact. The ultimate torsional strength of the bone-to-implant interface was determined immediately after implantation. Image superposition was used to analyze and quantify the contact situation between bone and implant within the femoral canal. Cortical contact was larger for the Prototype design with the additional set of splines compared to the Reclaim stem (p = 0.046), associated with a higher torsional stability (35.2 ± 6.0 Nm vs. 28.2 ± 3.5 Nm, p = 0.039). CONCLUSIONS: A second set of splines with reduced prominence could be shown to improve primary stability of a revision stem in the femoral diaphysis in the presence of significant proximal bone loss. The beneficial effect of varying spline size and number has the potential to further improve the longevity of revision hip stems.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Enfermedades Óseas Metabólicas , Humanos , Fémur/cirugía , Interfase Hueso-Implante , Exactitud de los Datos
3.
J Mech Behav Biomed Mater ; 140: 105742, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36857975

RESUMEN

BACKGROUND: Patient-specific 3D-printed miniplates for free flap fixation in mandibular reconstruction were recently associated with enhanced osseous union. Higher mechanical strains resulting from these plates are discussed as reasons, but biomechanical studies are missing. This study aims to examine, whether patient-specific 3D-printed miniplates provide an increased interosteotomy movement (IOM) and lower stiffness compared with reconstruction plates. METHODS: Polyurethane (PU) mandible and fibula models (Synbone AG, Malans, Schweiz) were used to simulate mandibular reconstruction with a one segment fibula flap equivalent. Osteosynthesis was performed using either four patient-specific 3D-printed miniplates (3D-Mini) or one patient-specific 3D-printed reconstruction plate (3D-Recon). Mastication was simulated using cyclic dynamic loading with increasing loads until material failure or a maximum load of 1000 N. Continuous IOM recording was carried out using a 3D optical tracking system (ARAMIS, Carl Zeiss GOM Metrology, Braunschweig, Germany). FINDINGS: The averaged stiffness at a load of 100-300 N load did not differ between the groups (p = 0.296). There was a faster 1.0 mm vertical displacement in the 3D-Mini group (26 376 ± 14 190 cycles versus 44 817 ± 30 430 cycles, p = 0.018). The IOM were higher with miniplate fixation in the distal gap (p = 0.040). In the mesial gap, there was no significant difference between the groups (p = 0.160). INTERPRETATION: Fixation with patient-specific 3D-printed miniplates results in higher mechanical strains. Lower rates of pseudarthrosis, as seen in clinical studies, might be caused by this phenomenon. Surgeons should evaluate the primary use of 3D-printed miniplates in mandibular reconstruction due to advantages of intraoral plate removal alongside safe osteosynthesis.


Asunto(s)
Reconstrucción Mandibular , Humanos , Reconstrucción Mandibular/métodos , Mandíbula/cirugía , Placas Óseas , Fijación Interna de Fracturas , Impresión Tridimensional
4.
World Neurosurg ; 152: e369-e376, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34087457

RESUMEN

OBJECTIVE: Loosening of pedicle screws is a frequently observed complication in spinal surgery. Because additional stabilization procedures such as cement augmentation or lengthening of the instrumentation involve relevant risks, optimal stability of the primarily implanted pedicle screw is of essential importance. The aim of the present study was to investigate the effect of increasing the screw diameter on pedicle screw stability. METHODS: A total of 10 human cadaveric vertebral bodies (L4) were included in the present study. The bone mineral density was evaluated using quantitative computed tomography and the pedicle diameter using computed tomography. The vertebrae underwent instrumentation using 6.0-mm × 45-mm pedicle screws on 1 side and screws with the largest possible diameter (8-10-mm × 45-mm) on the other side. Fatigue testing was performed by applying a cyclic loading (craniocaudal sinusoidal 0.5 Hz) with increasing peak force (100 N + 0.1 N/cycle) until screw head displacement of 5.4 mm was reached. RESULTS: The mean fatigue load was 334 N for the 6-mm diameter screws and was increased significantly to 454 N (+36%) for the largest possible diameter screws (P < 0.001). With an increase in the fatigue load by 52%, this effect was even more pronounced in vertebrae with reduced bone density (bone mineral density <120 mg/cm3; n = 7; P < 0.001). The stiffness of the construct was significantly greater in the largest diameter screw group compared with the standard screw group during the entire testing period (start, P < 0.001; middle, P < 0.001; end, P = 0.009). CONCLUSIONS: Increasing the pedicle screw diameter from a standard 6-mm screw to the largest possible diameter (8-10 mm) led to a significantly greater fatigue load.


Asunto(s)
Diseño de Equipo , Fenómenos Mecánicos , Tornillos Pediculares , Anciano , Cementos para Huesos , Densidad Ósea , Cadáver , Femenino , Humanos , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Fusión Vertebral , Columna Vertebral/diagnóstico por imagen , Columna Vertebral/cirugía , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
5.
Global Spine J ; 11(5): 679-685, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32875910

RESUMEN

STUDY DESIGN: Biomechanical study. OBJECTIVES: Failure of pedicle screws is a major problem in spinal surgery not only postoperatively, but also intraoperatively. The aim of this study was to evaluate whether cement augmentation may restore mounting of initially loosened pedicle screws. METHODS: A total of 14 osteoporotic or osteopenic human cadaveric vertebral bodies (L2)-according to quantitative computed tomography (QCT)-were instrumented on both sides by conventional pedicle screws and cement augmented on 1 side. In vitro fatigue loading (cranial-caudal sinusoidal, 0.5 Hz) with increasing peak force (100 N + 0.1 N/cycles) was applied until a screw head displacement of 5.4 mm (∼20°) was reached. After loosening, the nonaugmented screw was rescue augmented, and fatigue testing was repeated. RESULTS: The fatigue load reached 207.3 N for the nonaugmented screws and was significantly (P = .009) exceeded because of initial cement augmentation (300.6 N). The rescue augmentation after screw loosening showed a fatigue load of 370.1 N which was significantly higher (P < .001) compared with the nonaugmented screws. The impact of bone density on fatigue strength decreased from the nonaugmented to the augmented to the rescue-augmented screws and shows the greatest effect of cement augmentation on fatigue strength at low bone density. CONCLUSIONS: Rescue augmentation leads to similar or higher fatigue strengths compared with those of the initially augmented screws. Therefore, the cement augmentation of initially loosened pedicle screws is a promising option to restore adequate screw stability.

6.
Eur Spine J ; 30(1): 128-135, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32940741

RESUMEN

PURPOSE: Inadequate anchoring of pedicle screws in vertebrae with poor bone quality is a major problem in spine surgery. The aim was to evaluate whether a modified thread in the area of the pedicle could significantly improve the pedicle screw fatigue strength. METHODS: Fourteen human cadaveric vertebral bodies (L2 and L3) were used for in vitro testing. Bone density (BMD) was determined by quantitative computed tomography. Vertebral bodies were instrumented by standard pedicle screws with a constant double thread on the right pedicle and a partial doubling of the threads-quad thread-(cortical thread) in the area of the pedicle on the left pedicle. Pulsating sinusoidal, cyclic load (0.5 Hz) with increasing peak force (100 N + 0.1 N/cycles) was applied orthogonal to the screw axis. The baseline force remained constant (50 N). Fatigue test was terminated after exceeding 5.4-mm head displacement (~ 20° screw tilting). RESULTS: The mean fatigue load at failure was 264.9 N (1682 cycles) for the standard screws and was increased significantly to 324.7 N (2285 cycles) by the use of cortical threaded screws (p = 0.014). This effect is particularly evident in reduced BMD (standard thread 241.2 N vs. cortical thread 328.4 N; p = 0.016), whereas in the group of vertebrae with normal BMD no significant difference could be detected (standard thread 296.5 N vs. cortical thread 319.8 N; p = 0.463). CONCLUSIONS: Compared to a conventional pedicle screw, the use of a cortical threaded pedicle screw promises superior fatigue load in vertebrae with reduced bone quality.


Asunto(s)
Tornillos Pediculares , Fenómenos Biomecánicos , Densidad Ósea , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Tomografía Computarizada por Rayos X
7.
Global Spine J ; 11(7): 1089-1098, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32744071

RESUMEN

STUDY DESIGN: Biomechanical. OBJECTIVE: This study evaluates the biomechanical properties of lag-screws used in vertebral pincer fractures at the thoracolumbar junction. METHODS: Pincer fractures were created in 18 bisegmental human specimens. The specimens were assigned to three groups depending on their treatment perspective, either bolted, with the thread positioned in the cortical or cancellous bone, or control. The specimens were mounted in a servo-hydraulic testing machine and loaded with a 500 N follower load. They were consecutively tested in 3 different conditions: intact, fractured, and bolted/control. For each condition 10 cycles in extension/flexion, torsion, and lateral bending were applied. After each tested condition, a computed tomography (CT) scan was performed. Finally, an extension/flexion fatigue loading was applied to all specimens. RESULTS: Biomechanical results revealed a nonsignificant increase in stiffness in extension/flexion of the fractured specimens compared with the intact ones. For lateral bending and torsion, the stiffness was significantly lower. Compared with the fractured specimens, no changes in stiffness due to bolting were discovered. CT scans showed an increasing fracture gap during axial loading both in extension/flexion, torsion, and lateral bending in the control specimens. In bolted specimens, the anterior fragment was approximated, and the fracture gap nullified. This refers to both the cortical and the cancellous thread positions. CONCLUSION: The results of this study concerning the effect of lag-screws on pincer fractures appear promising. Though there was little effect on stiffness, CT scans reveal a bony contact in the bolted specimens, which is a requirement for bony healing.

8.
Eur J Trauma Emerg Surg ; 47(1): 187-193, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31463604

RESUMEN

PURPOSE: Biomechanical studies of the pelvis are usually performed using dissected pelvic specimens or synthetic bones. Thereby the stabilising effect of the surrounding soft tissues is analysed insufficiently. Biomechanical data for isolated anterior pelvic ring fractures are currently missing. Therefore, the purpose of this study was to develop a novel testing device for biomechanical analyses of the pelvis and to investigate two different anterior pelvic ring fractures in a cadaveric model with intact peripelvic soft tissues. METHODS: A new biomechanical table construction which enables the fixation and testing of complete cadaveric specimens was developed. It was used to investigate the relative motion and stiffness changes due to unilateral osteotomy of the superior and inferior pubic ramus. Five cadavers with a mean age of 55.6 years (± 15.53 years) were included and loaded with a sinusoidal, cyclic (1 Hz), compressive force of up to 365 N over ten cycles for each condition. RESULTS: Biomechanical testing of the pelvis with complete appended soft tissues was feasible. Native stiffness without a pelvic fracture was 64.31 N/mm (± 8.33 N/mm). A standardised unilateral osteotomy of the superior pubic ramus reduced the stiffness under isolated axial load by 2% (63.05 N/mm ± 7.45 N/mm, p = 0.690). Additional osteotomy of the inferior pubic ramus caused a further, statistically not significant, decrease by 5% (59.57 N/mm ± 6.84 N/mm, p = 0.310). CONCLUSIONS: The developed test device was successfully used for biomechanical analyses of the pelvis with intact peripelvic soft tissues. In a first study, isolated unilateral fractures of the anterior pelvic ring showed no relevant biomechanical variation compared to the intact situation under isolated axial load. Only 7% of the measured stiffness was created by both unilateral pubic rami. Therefore, the clinical practice to treat unilateral anterior pelvic ring fractures conservatively is supported by the results of this study.


Asunto(s)
Fracturas Óseas/fisiopatología , Huesos Pélvicos/lesiones , Fenómenos Biomecánicos , Cadáver , Módulo de Elasticidad , Humanos , Persona de Mediana Edad , Modelos Anatómicos , Modelos Biológicos , Estrés Mecánico
9.
J Mech Behav Biomed Mater ; 111: 104007, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32854074

RESUMEN

BACKGROUND: Titanium plate fixation of free flaps in mandibular reconstruction involves complications such as osseous non-union or imaging artefacts. Interosteotomy movement (IOM) is known to affect bone healing. This study aimed to compare IOM and mechanical integrity of four different fixation systems in a mandible reconstruction model. METHODS: Two polyurethane (PU) fibula segments were fixed in right-sided defects of PU mandibles. Laser-melted patient-specific titanium plates were fixed with non-locking-screws (Ti-NL) or locking-screws (Ti-L). The third group consisted of locking-screws for patient-specific polyetheretherketone (PEEK-L) plates. The last group used titanium miniplates and monocortical screw fixation (Ti-MP). All models were loaded unilaterally via cyclic dynamic loading with increasing loads to simulate mastication. IOM was registered using a 3D optical tracking system. FINDINGS: PEEK-L showed highest vertical displacement (p = 0.010), lowest stiffness (p = 0.004) and highest IOM (p = 0.001). All specimen in PEEK-L demonstrated abnormal bending (n = 5) or plate fracture (n = 1). Vertical displacement or stiffness did not differ between any of Ti-MP, Ti-L and Ti-NL. IOM in Ti-MP was higher than in Ti-L and Ti-NL (p = 0.001). INTERPRETATION: Mechanical integrity of all titanium plates complies with established standards. In this model, the screw system did not influence IOM. In the tested composition and shape, PEEK plates do not seem to guarantee sufficient mechanical integrity for a use in mandibular reconstruction. Thus modifications are needed. Future clinical studies are needed to clarify optimal IOM after mandible reconstruction.


Asunto(s)
Reconstrucción Mandibular , Titanio , Fenómenos Biomecánicos , Placas Óseas , Fijación Interna de Fracturas , Humanos
10.
Eur Spine J ; 29(6): 1297-1303, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32206868

RESUMEN

PURPOSE: Cement augmentation of pedicle screws is able to improve screw anchorage in osteoporotic vertebrae but is associated with a high complication rate. The goal of this study was to evaluate the impact of different cement volumes on pedicle screw fatigue strength. METHODS: Twenty-five human vertebral bodies (T12-L4) were collected from donors between 73 and 97 years of age. Bone density (BMD) was determined by quantitative computed tomography. Vertebral bodies were instrumented by conventional pedicle screws, and unilateral cement augmentation was performed. Thirteen vertebrae were augmented with a volume of 1 ml and twelve with a volume of 3 ml bone cement. A fatigue test was performed using a cranial-caudal sinusoidal, cyclic load (0.5 Hz) with increasing compression force (100 N + 0.1 N/cycles). RESULTS: The load to failure was 183.8 N for the non-augmented screws and was increased significantly to 268.1 N (p < 0.001) by cement augmentation. Augmentation with 1 ml bone cement increased the fatigue load by 41% while augmentation with 3 ml increased the failure load by 51% compared to the non-augmented screws, but there was no significant difference in fatigue loads between the specimens with screws augmented with 1 ml and screws augmented with 3 ml of bone cement (p = 0.504). CONCLUSION: Cement augmentation significantly increases pedicle screw stability. The benefit of augmentation on screw anchorage was not significantly affected by reducing the applied volume of cement from 3 ml to 1 ml. Considering the high risk of cement leakage during augmentation, we recommend the usage of a reduced volume of 1 ml bone cement for each pedicle screw. These slides can be retrieved under Electronic Supplementary Material .


Asunto(s)
Tornillos Pediculares , Fenómenos Biomecánicos , Cementos para Huesos , Densidad Ósea , Humanos , Vértebras Lumbares , Tomografía Computarizada por Rayos X
11.
PLoS One ; 14(11): e0225648, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31774856

RESUMEN

PURPOSE: The purpose of this study was to compare the biomechanical properties of an all-suture anchor to a conventional anchor used commonly in rotator cuff repairs. Furthermore, the biomechanical influence of various implantation angles was evaluated in both anchor types in a human cadaveric model. METHODS: 30 humeri were allocated into three groups with a similar bone density. The two different anchor types were inserted at a predefined angle of 45°, 90° or 110°. Biomechanical testing included an initial preload of 20N followed by a cyclic protocol with a stepwise increasing force of 0,05N for each cycle at a rate of 1Hz until system failure. Number of cycles, maximum load to failure, stiffness, displacement and failure mode were determined. RESULTS: 27 anchors failed by pullout. There was no significant difference between the conventional and the all-suture anchor regarding mean pullout strength. No considerable discrepancy in stiffness or displacement could be perceived. Comparing the three implantation angles no significant difference could be observed for the all-suture or the conventional anchor. CONCLUSION: All-suture anchors show similar biomechanical properties to conventional screw shaped anchors in an unlimited cyclic model. The exact insertion angle is not a significant predictor of failure.


Asunto(s)
Tornillos Óseos , Húmero/cirugía , Lesiones del Manguito de los Rotadores/cirugía , Manguito de los Rotadores/cirugía , Anclas para Sutura/clasificación , Técnicas de Sutura/instrumentación , Adulto , Anciano , Artroscopía , Fenómenos Biomecánicos , Cadáver , Humanos , Ensayo de Materiales , Persona de Mediana Edad , Anclas para Sutura/estadística & datos numéricos , Resistencia a la Tracción , Adulto Joven
12.
J Shoulder Elbow Surg ; 28(12): 2433-2437, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31311747

RESUMEN

HYPOTHESIS AND BACKGROUND: The possibility of implanting a conventional anchor at the pullout site following all-suture anchor failure was evaluated in a biomechanical cadaveric model. The hypothesis of the study was that anchor revision would yield equal biomechanical properties. METHODS: Ten human humeri were obtained, and bone density was determined via computed tomography. After all-suture anchor (n = 5) and conventional 4.5-mm anchor (n = 5) insertion, biomechanical testing was conducted. Following all-suture anchor pullout, a conventional 5.5-mm anchor was inserted at the exact site of pullout (n = 5) and biomechanical testing was reinitiated. Testing was conducted using an initial preload of 20 N, followed by an unlimited cyclic protocol, with a stepwise increasing force of 0.05 N for each cycle at a rate of 1 Hz until system failure. The number of cycles, maximum load to failure, stiffness, displacement, and failure mode, as well as macroscopic observation at the failure site including diameter, shape, and cortical destruction, were registered. RESULTS: The defect following all-suture pullout showed a mean diameter of 4 mm, and conventional revision was possible in each sample. There was no significant difference between the initial all-suture anchor implantation and the conventional anchor implantation or the conventional revision following all-suture failure regarding mean pullout strength, stiffness, displacement, or total number of cycles until failure. CONCLUSION: Conventional anchor revision at the exact same site where all-suture anchor pullout occurred is possible and exhibits similar biomechanical properties.


Asunto(s)
Húmero/cirugía , Falla de Prótesis , Articulación del Hombro/cirugía , Anclas para Sutura/efectos adversos , Anciano , Fenómenos Biomecánicos , Cadáver , Humanos , Persona de Mediana Edad , Reoperación
13.
Clin Biomech (Bristol, Avon) ; 63: 193-200, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30913462

RESUMEN

BACKGROUND: Using a new ceramic head with a titanium adapter sleeve offers the possibility of maintaining a well fixed stem when conducting cup revision of a total hip arthroplasty. The aim of this study is to test the impact of stem taper damage on the fracture strength of sleeved ceramic heads. METHODS: Pristine zirconia-toughened alumina heads with titanium adapter sleeves (BIOLOX®OPTION System) were tested on damaged Ti-4Al-6V stem tapers in accordance with ISO7206-10. Four distinctive damage types classified as intolerable by the manufacture were investigated, representing various reductions in contact area between the stem taper and sleeve taper as well as damage incurred from previous ceramic head fracture. FINDINGS: The largest reduction in fracture strength occurred for a loss of contact for the entire length of the stem taper. Nonetheless, the fracture strength in all investigated cases was several times higher than that defined by the FDA standards. INTERPRETATION: The use of a titanium sleeve recreates a uniform contact situation between the ceramic head and the outer sleeve taper in situations of damaged stem tapers. For the investigated damage types a high fracture strength of the ceramic head was maintained. This study supports the clinical use for sleeved ceramic heads in instances of greater damages of stem tapers than previously defined in order to spare patients from stem removal.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Cerámica/química , Prótesis de Cadera , Titanio/química , Óxido de Aluminio , Artroplastia de Reemplazo de Cadera/métodos , Simulación por Computador , Resistencia Flexional , Humanos , Ensayo de Materiales , Diseño de Prótesis , Falla de Prótesis , Programas Informáticos
14.
J Mech Behav Biomed Mater ; 91: 212-219, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30594831

RESUMEN

OBJECTIVES: Free flap fixation with patient specific titanium (TI) plates is commonly performed after oncologic mandible resection, but plate exposure, osseous nonunion and imaging artefacts are associated complications. The aim of this study was to analyze interfragmentary movements and fatigue behaviour of patient specific titanium plates in comparison to a novel glass fiber reinforced composite (GFRC) plate in vitro. METHODS: Two polyurethane fibula segments were fixed to a corresponding mandible (Synbone AG, Malans, CH) with a patient specific 2.0 mm titanium plate (DePuy Synthes, Umkirch, Germany and Materialise, Leuven, Belgium) or one of two patient specific GFRC plates with different glass fiber orientation. Plate fixation to the fibula segments was performed with monocortical non-locking screws in all groups. Plate fixation to the mandible was performed with bicortical locking screws in the titanium group and with bicortical non-locking screws in the GFRC groups. Mastication was simulated via cyclic dynamic loading on the left side at a rate of 1 Hz with increasing peak loading (+0.15 N/cycle, Bionix, MTS, Eden Prairie, USA). A three-dimensional optical measuring system (PONTOS 5 M, GOM, Braunschweig, Germany) was used to determine interfragmentary movements between mandible and fibula segments. RESULTS: Mean plate stiffness of GFRC plates was 431 ±â€¯64 N/mm and 453 ±â€¯70 N/mm versus 560 ±â€¯112 N/mm in the titanium group. No significant differences were found for the number of loading cycles until a vertical displacement of 1.0 mm (p = 0.637) and for vertical displacement over time (p = 0.490). Interosteotomy gap movement differed significantly between titanium and GFRC plates in the right distal (p = 0.001), intermediate (p = 0.006) and left distal gap (p = 0.025). CONCLUSIONS: CAD/CAM titanium plates with locking screws provide increased stiffness and reduced interosteotomy movements in comparison to CAD/CAM glass fiber reinforced composite plates with non-locking titanium screws. Future studies should evaluate the influence of mechanobiologically optimized fixation systems on bone healing in free flap surgery.


Asunto(s)
Vidrio , Ensayo de Materiales , Titanio , Fenómenos Biomecánicos , Humanos , Soporte de Peso
15.
Eur Spine J ; 27(8): 1964-1971, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29948322

RESUMEN

PURPOSE: Cement augmentation of pedicle screws is known to increase their mechanical strength. Aim was to evaluate the impact of cement augmentation on pedicle screw fatigue strength in dependence of the bone mineral density (BMD). METHODS: Twenty-one human L2 vertebral bodies from donors between 19 and 96 years of age were used for in vitro experiments. BMD was measured using quantitative computed tomography (QCT). Two pedicle screws were inserted in each specimen and unilaterally augmented with bone cement. Fatigue testing was performed using a cranio-caudal sinusoidal, cyclic load (0.5 Hz) with increasing compression force (100 N + 0.1 N/cycles). Results were evaluated for the BMD groups: normal: BMD > 120 mg/cm3, osteopenic: BMD 80-120 mg/cm3, and osteoporotic: BMD < 80 mg/cm3 bone mass. RESULTS: There was a significant correlation between fatigue force and BMD for the non-augmented and augmented screws (non-augmented R2 = 0.839, p < 0.001; augmented R2 = 0.551, p < 0.001). There was a significantly increased fatigue strength of the augmented screws over the non-augmented screws in the osteoporotic group (p = 0.001), while the differences in the other groups were not significant (normal p = 0.818/osteopenic p = 0.132). CONCLUSIONS: The benefit of pedicle screw cement augmentation significantly depends on the bone mineral density and has the greatest extent of increased fatigue strength in osteoporotic vertebrae. Preoperative measurement of the BMD is strongly recommended to predict the benefit of augmentation and reinforce the decision for cement augmentation. These slides can be retrieved under Electronic Supplementary Material.


Asunto(s)
Cementos para Huesos/uso terapéutico , Densidad Ósea/fisiología , Vértebras Lumbares/cirugía , Osteoporosis/fisiopatología , Tornillos Pediculares , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos/fisiología , Cadáver , Análisis de Falla de Equipo/métodos , Femenino , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/fisiopatología , Masculino , Ensayo de Materiales/métodos , Persona de Mediana Edad , Osteoporosis/diagnóstico por imagen , Falla de Prótesis , Tomografía Computarizada por Rayos X , Adulto Joven
16.
J Craniomaxillofac Surg ; 45(11): 1878-1883, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28943180

RESUMEN

BACKGROUND: CAD/CAM reconstruction plates have become a viable option for mandible reconstruction. The aim of this study was to determine whether CAD/CAM plates provide higher fatigue strength compared with conventional fixation systems. MATERIAL AND METHODS: 1.0 mm miniplates, 2.0 mm conventional locking plates (DePuy Synthes, Umkirch, Germany), and 2.0 mm CAD/CAM plates (Materialise, Leuven, Belgium/DePuy Synthes) were used to reconstruct a polyurethane mandible model (Synbone, Malans, CH) with cortical and cancellous bone equivalents. Mastication was simulated via cyclic dynamic testing using a universal testing machine (MTS, Bionix, Eden Prairie, MN, USA) until material failure reached a rate of 1 Hz with increasing loads on the left side. RESULTS: No significant difference was found between the groups until a load of 300 N. At higher loads, vertical displacement differed increasingly, with a poorer performance of miniplates (p = 0.04). Plate breakage occurred in miniplates and conventional locking plates. Screw breakage was recorded as the primary failure mechanism in CAD/CAM plates. Stiffness was significantly higher with the CAD/CAM plates (p = 0.04). CONCLUSION: CAD/CAM plates and reconstruction plates provide higher fatigue strength than miniplates, and stiffness is highest in CAD/CAM systems. All tested fixation methods seem sufficiently stable for mandible reconstruction.


Asunto(s)
Placas Óseas , Diseño Asistido por Computadora , Reconstrucción Mandibular/instrumentación , Fenómenos Biomecánicos , Trasplante Óseo , Diseño de Equipo , Humanos , Ensayo de Materiales , Estrés Mecánico , Resistencia a la Tracción
17.
Eur Spine J ; 26(11): 2891-2897, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28391382

RESUMEN

PURPOSE: Loosening of pedicle screws is one major complication of posterior spinal stabilisation, especially in the patients with osteoporosis. Augmentation of pedicle screws with cement or lengthening of the instrumentation is widely used to improve implant stability in these patients. However, it is still unclear from which value of bone mineral density (BMD) the stability of pedicle screws is insufficient and an additional stabilisation should be performed. The aim of this study was to investigate the correlation of bone mineral density and pedicle screw fatigue strength as well as to define a threshold value for BMD below which an additional stabilisation is recommended. METHODS: Twenty-one human T12 vertebral bodies were collected from donors between 19 and 96 years of age and the BMD was measured using quantitative computed tomography. Each vertebral body was instrumented with one pedicle screw and mounted in a servo-hydraulic testing machine. Fatigue testing was performed by implementing a cranio-caudal sinusoidal, cyclic (0.5 Hz) load with stepwise increasing peak force. RESULTS: A significant correlation between BMD and cycles to failure (r = 0.862, r 2 = 0.743, p < 0.001) as well as for the linearly related fatigue load was found. Specimens with BMD below 80 mg/cm3 only reached 45% of the cycles to failure and only 60% of the fatigue load compared to the specimens with adequate bone quality (BMD > 120 mg/cm3). CONCLUSIONS: There is a close correlation between BMD and pedicle screw stability. If the BMD of the thoracolumbar spine is less than 80 mg/cm3, stability of pedicle screws might be insufficient and an additional stabilisation should be considered.


Asunto(s)
Densidad Ósea , Osteoporosis , Tornillos Pediculares , Fusión Vertebral , Vértebras Torácicas , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Análisis de Falla de Equipo , Humanos , Persona de Mediana Edad , Osteoporosis/diagnóstico por imagen , Osteoporosis/cirugía , Fusión Vertebral/efectos adversos , Fusión Vertebral/instrumentación , Fusión Vertebral/estadística & datos numéricos , Vértebras Torácicas/diagnóstico por imagen , Vértebras Torácicas/cirugía , Tomografía Computarizada por Rayos X , Adulto Joven
18.
Knee Surg Sports Traumatol Arthrosc ; 25(7): 2025-2031, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26685688

RESUMEN

PURPOSE: To evaluate different stabilisation techniques for acromioclavicular (AC) joint separations, including direct AC repair, and to compare the properties of the stabilised and native joints. METHODS: An established in vitro testing model for the AC joint was used to analyse joint stability after surgical reconstruction [double TightRope (DTR), DTR with AC repair (DTR + AC), single TR with AC repair (TR + AC), and PDS sling with AC repair (PDS + AC)]. Twenty-four human cadaveric shoulders were randomised by age into four testing groups. Joint stiffness was measured by applying an axial load during defined physiological ranges of motion. Similar tests were performed for the native joints, after dissecting the coracoclavicular and AC ligaments, and after surgical reconstruction. Cyclic loading was performed for 1000 cycles with 20-70 N and vertical load to failure determined after cyclic testing. RESULTS: Axial stiffness for all TR groups was significantly higher than for the native joint (DTR 38.94 N/mm, p = 0.005; DTR + AC 37.79 N/mm, p = 0.015; TR + AC 45.61 N/mm, p < 0.001 vs. native 26.05 N/mm). The axial stiffness of the PDS + AC group was similar to that of the native joint group (21.4 N/mm, n.s.). AC repair did not significantly influence rotational stiffness. Load to failure was similar and >600 N in all groups (n.s.). CONCLUSION: Reconstruction of AC dislocations with one or two TRs leads to stable results with a higher stiffness than the native joints. For the PDS + AC group, axial stiffness was similar to the native situation, although there might be a risk of elongation. Direct AC repair showed no significantly increased stability in comparison with reconstructions without direct AC repair. Thus, a direct AC repair seems to be dispensable in clinical practice, while TRs or PDS cerclages appear to provide sufficiently stable results.


Asunto(s)
Articulación Acromioclavicular/cirugía , Luxaciones Articulares/cirugía , Ligamentos Articulares/cirugía , Ensayo de Materiales , Dispositivos de Fijación Ortopédica , Cinta Quirúrgica , Adulto , Anciano , Fenómenos Biomecánicos , Cadáver , Femenino , Humanos , Inestabilidad de la Articulación/cirugía , Masculino , Persona de Mediana Edad , Distribución Aleatoria , Soporte de Peso
19.
Proc Inst Mech Eng H ; 230(7): 690-9, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27170535

RESUMEN

Bi-modular hip arthroplasty prostheses allow adaptation to the individual patient anatomy and the combination of different materials but introduce an additional interface, which was related lately to current clinical issues. Relative motion at the additional taper interface might increase the overall risk of fretting, corrosion, metallic debris and early failure. The aim of this study was to investigate whether the assembly force influences the relative motion and seating behaviour at the stem-neck interface of a bi-modular hip prosthesis (Metha(®); Aesculap AG, Tuttlingen, Germany) and whether this relation is influenced by the taper angle difference between male and female taper angles. Neck adapters made of titanium (Ti6Al4V) and CoCr (CoCr29Mo) were assembled with a titanium stem using varying assembly forces and mechanically loaded. A contactless eddy current measurement system was used to record the relative motion between prosthesis stem and neck adapter. Higher relative motion was observed for Ti neck adapters compared to the CoCr ones (p < 0.001). Higher assembly forces caused increased seating distances (p < 0.001) and led to significantly reduced relative motion (p = 0.019). Independent of neck material type, prostheses with larger taper angle difference between male and female taper angles exhibited decreased relative motion (p < 0.001). Surgeons should carefully use assembly forces above 4 kN to decrease the amount of relative motion within the taper interface. Maximum assembly forces, however, should be limited to prevent periprosthetic fractures. Manufacturers should optimize taper angle differences to increase the resistance against relative motion.


Asunto(s)
Prótesis de Cadera , Aleaciones , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Fenómenos Biomecánicos , Humanos , Ensayo de Materiales , Movimiento (Física) , Diseño de Prótesis , Falla de Prótesis , Estrés Mecánico , Titanio , Vitalio
20.
Ind Health ; 54(4): 308-14, 2016 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-26829975

RESUMEN

An in-vitro experiment was designed to investigate the mode of failure following shear fatigue loading of lumbar motion-segments. Human male lumbar motion-segments (age 32-42 years, n=6) were immersed in Ringer solution at 37°C and repeatedly loaded, using a modified materials testing machine. Fatigue loading consisted of a sinusoidal shear load from 0 N to 1,500 N (750 N±750 N) applied to the upper vertebra of the motion-segment, at a frequency of 5 Hz. During fatigue experiments, several failure events were observed in the dynamic creep curves. Post-test x-ray, CT and dissection revealed that all specimens had delamination of the intervertebral disc. Anterior shear fatigue predominantly resulted in fracture of the apophyseal processes of the upper vertebrae (n=4). Exposure to the anterior shear fatigue loading caused motion-segment instability and resulted in vertebral slip corresponding to grade I and 'mild' grade II spondylolisthesis, as observed clinically.


Asunto(s)
Vértebras Lumbares/lesiones , Estrés Mecánico , Vibración/efectos adversos , Adulto , Fracturas por Estrés/patología , Humanos , Técnicas In Vitro , Disco Intervertebral/lesiones , Disco Intervertebral/patología , Vértebras Lumbares/patología , Masculino , Resistencia al Corte , Espondilolistesis/patología